CODAN 5900 series VSAT Ku-Band high power transceivers offer a wide range of distinctive advantages and enhanced features for satellite communications systems based in remote or challenging geographic regions.
Available in single or dual synthesiser options, Ku-Band frequency bands and 70 or 140MHz IF configurations-and a range of power outputs- CODAN 5900 series VSAT transceivers provide industry leading technical performance.
Key features
Durability
The CODAN 5900 series VSAT transceivers are designed and tested to meet their performance specifications in an ambient temperature range from -40°C to +55°C, ensuring long-term survival in extreme conditions. Field experience shows that MTBFs of greater than 60,000 hours can be expected.
RF performance
RF performance is superb, particularly intermodulation performance, gain stability over temperature and flatness across the IF band.
These transceivers also boast industry leading spurious and harmonics specifications while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with RF transceiver variations. The high linearity and low spurious characteristics contribute to superior multi-carrier performance.
Output power options
The CODAN 5900 series Ku-Band VSAT transceiver is available with 40 watts output rating.
Power consumption
CODAN high power VSAT transceivers low power consumption and low temperature rise, ensuring internal components do not suffer undue stress.
Power supply
All the high power transceivers are AC mains powered and may be field selected to operate from either 115 V AC or 230 V AC.
Internal protection
Internal protection against high temperature and short or open circuit RF output is standard.
Advanced features

Enhanced monitor and control
All operating functions can be controlled and monitored via the serial interface, and the operating configuration is stored in EEPROM to ensure the set-up parameters are restored in the event of a power failure.
Universal interface compatibility
The CODAN 5900 series VSAT transceivers has universal interface compatibility capable of operating with dumb terminals, laptop/PC emulating terminals, handheld terminals and personal organisers without requiring proprietary software. The versatile configuration options support contact closure, RS232, RS422 and RS485 (2 or 4 wire).
Two dedicated controllers are available from Codan:
- CODAN 5560 Hand-Held Controller, suitable for in the field installation setup
- CODAN 5570 Remote Controller, suitable for indoor rack mounting to provide permanent monitoring and control capabilities
Redundancy switching system
A redundancy switching system is available to provide an automatic changeover to a second transceiver to maximise availability and minimise any disruption to service. This system is fully outdoor mounted, but can be supplied with the CODAN 5587 Redundant System Monitor to provide indoor monitoring and control.
Major configuration options
VSAT Ku-Band transmit frequency band (GHz) - Transmit
|
1 VSAT Ku-Band standard
|
14.00-14.50
|
VSAT Ku-Band receive frequency bands
All systems use the common CODAN 5900 series VSAT converter module, which has an RF input of 950-1700 MHz. Receive bands are selected by the use of an appropriate LNB. Standard frequency bands are listed below.
VSAT Ku Band LNB (Standard noise temperature 90 K)
|
Band 1
|
10.95-11.7 GHz |
| Band 2 |
11.7-12.2 GHz |
| Band 3 |
12.25-12.75 GHz |
(LNBs are phase locked to the internal 10 MHz reference in the 5900 converter module).
Bandwidth
|
N - Narrow band (40MHz)
|
Field selectable 70 or 140MHz IF
|
|
W - Wide band (80 MHz)
|
140 MHz IF only
|
Output power
|
VSAT Ku-Band: 40W
|
WR75 waveguide output standard |
Options and accessories
- CODAN Hand-Held Controller
- CODAN Remote Controller
- CODAN Redundancy Switching Systems
- CODAN Transmit Reject Filters
- CODAN Antenna Mounting Kits
CODAN quality and service
The high power transceivers are built and tested in CODAN ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance monitoring.
CODAN fully trained staff and agents provide in-factory and in-country training services and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.
Technical specifications
Transmit section
IF input
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz
|
|
Impedance
|
50/75 Ω selectable
|
| Connector |
N-type female
|
| Return loss |
18 dB minimum at 50 Ω |
Gain specification
Gain
|
78 dB minimum (0 dB SSPA & Converter attenuator settings)
|
| Attenuator ranges |
0 to 25 dB nominal (Converter)
0 to 20 dB nominal (SSPA)
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Over IF
Narrow BW option
Wide BW option
Over frequency range
|
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz
±2.0 dB maximum
|
| Gain stability |
+1.5 dB maximum, -40°C to +50°C
|
RF output
|
Frequency range
|
14.0 to 14.5 GHz
|
|
Connector
|
WR75
|
|
VSWR
|
1.25:1 maximum
|
| Output power (1 dB GCP) |
+46 dBm (40W) minimum at 25°C |
| Carrier to intermodulation ratio |
-25 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP |
| Spurious output |
-60 dBc maximum at 1 dB GCP
|
| Harmonics |
-50 dBc maximum at 1 dB GCP
|
Phase noise (SSB)*
|
100 Hz
|
-60 dBc/Hz maximum
|
|
1 kHz
|
-70 dBc/Hz maximum
|
| 10 kHz |
-75 dBc/Hz maximum
|
| 100 kHz |
--85 dBc/Hz maximum |
Synthesiser step size
|
Synthesiser step size
|
1 MHz
|
Frequency stability
|
-40°C to +55°C
|
±2õ10-8
|
|
Aging
|
±1õ10-7/year
|
Receive section (excluding LNB)
RF input
|
Frequency range
|
950 to 1700 MHz
|
|
Impedance
|
50 Ω
|
|
Connector
|
N-type female
|
|
VSWR
|
1.4:1 maximum |
| Noise figure |
20 dB typical |
|
DC output (switch selectable)
|
+15 V @ 75 to 400mA
|
| 10 MHz output |
0 dBm + 1 dB |
IF output
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz
|
|
Impedance
|
50/75 Ω selectable
|
| 3rd order intercept |
+15 dBm minimum |
|
Connector
|
N-type female
|
|
Return loss
|
18 dB minimum at 50 Ω
|
Gain specification
|
Gain
|
35 dB nominal
|
|
Attenuator range
|
0 dB to 25 dB nominal
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Over IF
Narrow BW option
Wide BW option
Over frequency range |
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz
+2.0 dB maximum
|
| Gain stability |
±3.0 dB maximum, -40°C to +55°C
|
| Image rejection |
50 dB minimum |
|
Spurious output
|
-65 dBm maximum
|
Phase noise (SSB)*
|
100 Hz
|
-60 dBc/Hz maximum
|
|
1 kHz
|
-70 dBc/Hz maximum
|
|
10 kHz
|
-80 dBc/Hz maximum
|
| 100 kHz |
-90 dBc/Hz maximum
|
Synthesiser step size
|
Synthesiser step size
|
1 MHz
|
Frequency stability
|
-40°C to +55°C
|
±2õ10-8
|
|
Aging
|
±1õ10-7/year
|
Low noise block cconverter
Indicative specifications.
Input
|
Pass band
|
10.95 to 12.75 GHz
|
|
Insertion loss
|
0.05 dB maximum
|
|
Reject band
|
13.75 to 14.5 GHz
|
|
Rejection
|
55 dB minimum
|
Noise figure
|
Noise figure
|
1.2 dB @ 25°C maximum
1.0 dB typical
|
Gain specification
|
Gain
|
60 dB typical
|
|
Gain flatness
|
±1.5 dB minimum maximum full band
|
Output
|
1 dB GCP
|
0 dBm minimum
|
|
3rd order intercept
|
+11 dBm minimum
|
|
Impedance
|
50 Ω
|
| Connector |
N-type female
|
| VSWR |
1.5:1 typical |
Transmit reject filter (optional)
|
Frequency range
VSAT Band 1
VSAT Band 2
VSAT Band 3
|
10.95 to 11.7 GHz
11.7 to 12.2 GHz
12.25 to 12.75 GHz
|
|
Interface
|
WR75
|
|
VSWR
|
2.5:1 typical
|
Monitor and control
Monitor and control facilities (converter)
|
Indicators
|
Standby, On, Warm-up, SSPA activated, Converter fault, LNB fault, SSPA fault, Temperature fault.
|
|
Controls
|
Power control (off/standby/on), SSPA control (inhibit/remote/ activate), Serial interface settings, LNB supply via Rx RF input connector, Mains/Battery supply select.
|
Remote monitor and control facilities (only via converter)
|
Serial interface standards
|
RS 232, RS 422(RS 485)
|
|
Protocol standards
|
ASCII, Packet (RS 485)
|
| Packet protocol address range |
0 to 127 |
Monitor and control facilities (SSPA)
|
Indicators
|
Online, Alarm, Standby, Maintenance
|
| Display |
Output power, Heatsink temperature, Alarms |
|
Controls
|
State, Gain
|
All dimensions are measured over the connectors.